#!HEAD: dcsm-EF_MEA_HV_ON 2020-03-17 07:23:44 328 45 MMO DCSM // EARTH FLY BY 8001 # MMMMMMMMMMMMMMMMMMMMMMMMOMMMMMMMMMMMMMMMMMMMMMMMMMMMOMMMMMMMMMMMMMMMMMMMMM 8002 # 8003 # 2.MEA ON, HV ON from 2020-04-09 21:40 until 2020-04-10 00:40 when we will turn OFF completely MEA 8004 # 8005 # MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMOMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMOMMMMM 8006 # -------------------------------------------------------------------------- 8007 # 2.0.1. DISABLE HV SECURITY (MCP + SPHERES) 8008 # -------------------------------------------------------------------------- 8009 # 8010 MEA1.HV_EN 8011 WAIT_SEC 2 8012 MEA2.HV_EN 8013 WAIT_SEC 40 8014 # 8015 # the HK 8016 CHECK MEA1.l1_cmd_exe =0x1D00 8017 CHECK MEA2.l1_cmd_exe =0x1D00 8018 # -------------------------------------------------------------------------- 8019 # 2.0.1. DISABLE MCP SECURITY 8020 # -------------------------------------------------------------------------- 8021 MEA1.MCP_ON 0x00 8022 WAIT_SEC 2 8023 MEA2.MCP_ON 0x00 8024 WAIT_SEC 40 8025 # 8026 CHECK MEA1.l1_cmd_exe =0x1C00 8027 CHECK MEA2.l1_cmd_exe =0x1C00 8028 # 8029 # -------------------------------------------------------------------------- 8030 # 2.0.2. Disable the MCP bit security 8031 # -------------------------------------------------------------------------- 8032 # 8033 MEA1.SECRTY_OFF 8034 WAIT_SEC 2 8035 MEA2.SECRTY_OFF 8036 WAIT_SEC 40 8037 # 8038 CHECK MEA1.l1_cmd_exe =0x1F00 8039 CHECK MEA2.l1_cmd_exe =0x1F00 8040 # 8041 # ========================================================================== 8042 # 2.1. ENABLE HV of ANALYZER 8043 # ========================================================================== 8044 # 8045 # Desactive the current limiter switch OFF (just for switch ON the HV) 8046 MEA1.ON_F12V 8047 WAIT_SEC 2 8048 MEA2.ON_F12V 8049 WAIT_SEC 2 8050 # 8051 # the HK 8052 # CHECK MEA1.l1_cmd_exe =0x3F00 8053 # CHECK MEA2.l1_cmd_exe =0x3F00 8054 # 8055 # 8056 #Switch ON the HV Spheres of analyzer 8057 MEA1.Anlyz_ON 8058 WAIT_SEC 2 8059 MEA2.Anlyz_ON 8060 WAIT_SEC 40 8061 # 8062 # the HK 8063 CHECK MEA1.l1_cmd_exe =0x3F00 8064 CHECK MEA2.l1_cmd_exe =0x3F00 8065 # 8066 # 8067 # Re-active the current limiter switch OFF 8068 MEA1.AUTO12V 8069 WAIT_SEC 2 8070 MEA2.AUTO12V 8071 WAIT_SEC 40 8072 # 8073 # the HK 8074 # CHECK MEA1.l1_cmd_exe =0x3E00 8075 # CHECK MEA2.l1_cmd_exe =0x3E00 8076 # 8077 # ========================================================================== 8078 # 2.2. SWITCH ON MCP 8079 # ========================================================================== 8080 # 8081 # The next commands can be sent in one time until we reach 1600 V 8082 # 8083 MEA1.MCP_ON 0x00 8084 WAIT_SEC 2 8085 MEA2.MCP_ON 0x00 8086 WAIT_SEC 60 8087 # 8088 # the HK 8089 # CHECK MEA1.l1_cmd_exe =0x1c00 8090 # CHECK MEA2.l1_cmd_exe =0x1c00 8091 # CHECK MEA1.HK_MCP : < 0V 8092 # CHECK MEA2.HK_MCP : < 0V 8093 # 8094 # 8095 MEA1.MCP_ON 0x0E 8096 WAIT_SEC 2 8097 MEA2.MCP_ON 0x0E 8098 WAIT_SEC 60 8099 # 8100 # the HK 8101 # CHECK MEA1.l1_cmd_exe =0x1c0E 8102 # CHECK MEA1.HK_MCP : ~ 200V 8103 # CHECK MEA2.l1_cmd_exe =0x1c0E 8104 # CHECK MEA2.HK_MCP : ~ 200V 8105 # 8106 MEA1.MCP_ON 0x1D 8107 WAIT_SEC 2 8108 MEA2.MCP_ON 0x1D 8109 WAIT_SEC 60 8110 # 8111 # the HK 8112 # CHECK MEA1.l1_cmd_exe =0x1c1d 8113 # CHECK MEA1.HK_MCP : ~ 400V 8114 # CHECK MEA2.l1_cmd_exe =0x1c1d 8115 # CHECK MEA2.HK_MCP : ~ 400V 8116 # 8117 # 8118 MEA1.MCP_ON 0x2B 8119 WAIT_SEC 2 8120 MEA2.MCP_ON 0x2B 8121 WAIT_SEC 60 8122 # 8123 # the HK 8124 # CHECK MEA1.l1_cmd_exe =0x1c2b 8125 # CHECK MEA1.HK_MCP : ~ 600V 8126 # CHECK MEA2.l1_cmd_exe =0x1c2b 8127 # CHECK MEA2.HK_MCP : ~ 600V 8128 # 8129 # 8130 MEA1.MCP_ON 0x3A 8131 WAIT_SEC 2 8132 MEA2.MCP_ON 0x3A 8133 WAIT_SEC 60 8134 # 8135 # the HK 8136 # CHECK MEA1.l1_cmd_exe =0x1c3a 8137 # CHECK MEA1.HK_MCP : ~ 800V 8138 # CHECK MEA2.l1_cmd_exe =0x1c3a 8139 # CHECK MEA2.HK_MCP : ~ 800V 8140 # 8141 # 8142 MEA1.MCP_ON 0x48 8143 WAIT_SEC 2 8144 MEA2.MCP_ON 0x48 8145 WAIT_SEC 60 8146 # 8147 # the HK 8148 # CHECK MEA1.l1_cmd_exe =0x1c48 8149 # CHECK MEA1.HK_MCP : ~ 1000V 8150 # CHECK MEA2.l1_cmd_exe =0x1c48 8151 # CHECK MEA2.HK_MCP : ~ 1000V 8152 # 8153 # 8154 MEA1.MCP_ON 0x57 8155 WAIT_SEC 2 8156 MEA2.MCP_ON 0x57 8157 WAIT_SEC 60 8158 # 8159 # the HK 8160 # CHECK MEA1.l1_cmd_exe =0x1c57 8161 # CHECK MEA1.HK_MCP : ~ 1200V 8162 # CHECK MEA2.l1_cmd_exe =0x1c57 8163 # CHECK MEA2.HK_MCP : ~ 1200V 8164 # 8165 # 8166 MEA1.MCP_ON 0x65 8167 WAIT_SEC 2 8168 MEA2.MCP_ON 0x65 8169 WAIT_SEC 60 8170 # 8171 # the HK 8172 # CHECK MEA1.l1_cmd_exe =0x1c65 8173 # CHECK MEA1.HK_MCP : ~ 1400V 8174 # CHECK MEA2.l1_cmd_exe =0x1c65 8175 # CHECK MEA2.HK_MCP : ~ 1400V 8176 # 8177 # 8178 MEA1.MCP_ON 0x74 8179 WAIT_SEC 2 8180 MEA2.MCP_ON 0x74 8181 WAIT_SEC 180 8182 # 8183 # the HK 8184 CHECK MEA1.l1_cmd_exe =0x1c74 8185 CHECK MEA1.HK_MCP : ~ 1600V 8186 CHECK MEA2.l1_cmd_exe =0x1c74 8187 CHECK MEA2.HK_MCP : ~ 1600V 8188 # The next commands can be sent in one time until we reach 2200 V 8189 # 8190 MEA1.MCP_ON 0x7B 8191 WAIT_SEC 2 8192 MEA2.MCP_ON 0x7B 8193 WAIT_SEC 60 8194 # 8195 # the HK 8196 # CHECK MEA1.l1_cmd_exe =0x1c7b 8197 # CHECK MEA1.HK_MCP : ~ 1700V 8198 # CHECK MEA2.l1_cmd_exe =0x1c7b 8199 # CHECK MEA2.HK_MCP : ~ 1700V 8200 # 8201 MEA1.MCP_ON 0x83 8202 WAIT_SEC 2 8203 MEA2.MCP_ON 0x83 8204 WAIT_SEC 60 8205 # 8206 # the HK 8207 # CHECK MEA1.l1_cmd_exe =0x1c83 8208 # CHECK MEA1.HK_MCP : ~ 1800V 8209 # CHECK MEA2.l1_cmd_exe =0x1c83 8210 # CHECK MEA2.HK_MCP : ~ 1800V 8211 # 8212 MEA1.MCP_ON 0x8A 8213 WAIT_SEC 2 8214 MEA2.MCP_ON 0x8A 8215 WAIT_SEC 60 8216 # 8217 # the HK 8218 # CHECK MEA1.l1_cmd_exe =0x1c8a 8219 # CHECK MEA1.HK_MCP : ~ 1900V 8220 # CHECK MEA2.l1_cmd_exe =0x1c8a 8221 # CHECK MEA2.HK_MCP : ~ 1900V 8222 # 8223 # 8224 MEA1.MCP_ON 0x91 8225 WAIT_SEC 2 8226 MEA2.MCP_ON 0x91 8227 WAIT_SEC 60 8228 # 8229 # the HK 8230 # CHECK MEA1.l1_cmd_exe =0x1c91 8231 # CHECK MEA1.HK_MCP : ~ 2000V 8232 # CHECK MEA2.l1_cmd_exe =0x1c91 8233 # CHECK MEA2.HK_MCP : ~ 2000V 8234 # 8235 MEA1.MCP_ON 0x98 8236 WAIT_SEC 2 8237 MEA2.MCP_ON 0x98 8238 WAIT_SEC 60 8239 # 8240 # the HK 8241 # CHECK MEA1.l1_cmd_exe =0x1c98 8242 # CHECK MEA1.HK_MCP : ~ 2100V 8243 # CHECK MEA2.l1_cmd_exe =0x1c98 8244 # CHECK MEA2.HK_MCP : ~ 2100V 8245 # 8246 # 8247 MEA1.MCP_ON 0xA0 8248 WAIT_SEC 2 8249 MEA2.MCP_ON 0xA0 8250 WAIT_SEC 180 8251 # 8252 # the HK 8253 CHECK MEA1.l1_cmd_exe =0x1ca0 8254 # CHECK MEA1.HK_MCP : ~ 2200V 8255 CHECK MEA2.l1_cmd_exe =0x1ca0 8256 # CHECK MEA2.HK_MCP : ~ 2200V 8257 # 8258 # 8259 MEA1.MCP_ON 0xA7 8260 WAIT_SEC 2 8261 MEA2.MCP_ON 0xA7 8262 WAIT_SEC 60 8263 # 8264 # the HK 8265 CHECK MEA1.l1_cmd_exe =0x1ca7 8266 # CHECK MEA1.HK_MCP : ~ 2300V 8267 CHECK MEA2.l1_cmd_exe =0x1ca7 8268 # CHECK MEA2.HK_MCP : ~ 2300V 8269 # 8270 # 8271 MEA1.MCP_ON 0xAE 8272 WAIT_SEC 2 8273 MEA2.MCP_ON 0xAE 8274 WAIT_SEC 60 8275 # 8276 # the HK 8277 CHECK MEA1.l1_cmd_exe =0x1cae 8278 # CHECK MEA1.HK_MCP : ~ 2400V 8279 CHECK MEA2.l1_cmd_exe =0x1cae 8280 # CHECK MEA2.HK_MCP : ~ 2400V 8281 # 8282 # 8283 MEA1.MCP_ON 0xB6 8284 WAIT_SEC 2 8285 MEA2.MCP_ON 0xB6 8286 WAIT_SEC 60 8287 # 8288 # the HK 8289 CHECK MEA1.l1_cmd_exe =0x1cb6 8290 # CHECK MEA1.HK_MCP : ~ 2500V 8291 CHECK MEA2.l1_cmd_exe =0x1cb6 8292 # CHECK MEA2.HK_MCP : ~ 2500V 8293 # 8294 # 8295 MEA1.MCP_ON 0xBD 8296 WAIT_SEC 2 8297 MEA2.MCP_ON 0xBD 8298 WAIT_SEC 60 8299 # 8300 # the HK 8301 CHECK MEA1.l1_cmd_exe =0x1cbd 8302 # CHECK MEA1.HK_MCP : ~ 2600V 8303 CHECK MEA2.l1_cmd_exe =0x1cbd 8304 # CHECK MEA2.HK_MCP : ~ 2600V 8305 # 8306 MEA1.MCP_ON 0xC4 8307 WAIT_SEC 2 8308 MEA2.MCP_ON 0xC4 8309 WAIT_SEC 60 8310 # 8311 # the HK 8312 CHECK MEA1.l1_cmd_exe =0x1cc4 8313 # CHECK MEA1.HK_MCP : ~ 2700V 8314 CHECK MEA2.l1_cmd_exe =0x1cc4 8315 # CHECK MEA2.HK_MCP : ~ 2700V 8316 # 8317 # 8318 MEA1.MCP_ON 0xC8 8319 WAIT_SEC 2 8320 MEA2.MCP_ON 0xC8 8321 WAIT_SEC 60 8322 # 8323 # the HK 8324 CHECK MEA1.l1_cmd_exe =0x1cc8 8325 # CHECK MEA1.HK_MCP : ~ 2750V 8326 CHECK MEA2.l1_cmd_exe =0x1cc8 8327 # CHECK MEA2.HK_MCP : ~ 2750V 8328 # 8999 EXIT